tools.petrov.re


194 tools in 22 categories. A title opens the tool; the language codes open it in that language.

Nuclear Physics & Radiation 4

Nuclear Engineering, Safety & Fuel 12

Thermodynamics, Heat & Fluid Flow 8

  • Steam Tables (IAPWS-IF97)Thermodynamic properties of water and steam per IAPWS-IF97. Specify any two properties to compute the rest across the saturation and superheated regions, with built-in validation checkpoints.Benchmark tested · 299/299 · Benchmark reportEN UA DE NL FR ES PL
  • Thermodynamic CyclesVapour power and refrigeration cycles — Rankine with reheat or regenerative feedwater heating, and vapour-compression with an internal heat exchanger, two-stage flash economiser or transcritical CO2 — for nine working fluids, plotted on T–s, h–s, lg p–h, lg p–v and T–h diagrams.Benchmark tested · 57/57 · Benchmark reportEN UA DE NL FR ES PL
  • Gas Dynamics LaboratoryExplore Laval nozzles, choking and moving normal shocks, Fanno, Rayleigh, oblique-shock, Prandtl–Meyer and shock-tube flows, plus unsteady 1D Euler transients.Benchmark tested · 257/257 · Benchmark reportEN UA DE NL FR ES PL
  • Mollier i–d / Psychrometric ChartPsychrometric (Mollier i–d) chart for moist air. Plot air states and HVAC processes and read enthalpy, moisture content, dew-point and wet-bulb temperatures.Benchmark tested · 115/115 · Benchmark reportEN UA DE NL FR ES PL
  • 2D Heat TransferInteractive two-dimensional temperature-field model. Define materials and boundary conditions, then inspect temperatures, gradients, isotherms and heat-flow paths.Benchmark tested · 12/12 · Benchmark reportEN UA DE NL FR ES PL
  • Moody Diagram & Pipe FrictionInteractive Moody diagram for internal pipe flow. Set Reynolds number and relative roughness to identify the flow regime and obtain the Darcy friction factor for pressure-loss calculations.Benchmark tested · 145/145 · Benchmark reportEN UA DE NL FR ES PL
  • Pump & Fan Operating PointExplore pump and fan operating points by changing system resistance, speed, density and parallel machines; inspect efficiency, power, NPSH or stability, and where pressure is spent.Benchmark tested · 158/158 · Benchmark reportEN UA DE NL FR ES PL
  • Heat Exchanger CalculatorRating and sizing of plate, wide-gap plate, shell-and-tube, double-pipe, finned air coil and pulsating push-pull exchangers.Benchmark tested · 263/263 · Benchmark reportEN UA DE NL FR ES PL

Pipe & Vessel Transients 10

HVAC & Indoor Climate 12

Acoustics & Noise 6

Building Physics & Envelope 9

Electrical Engineering 6

Control & Systems 9

  • Hydraulic Network SolverDraw an arbitrary network of pipes, nodes, pumps, valves and heat exchangers and solve the steady-state flows and pressures.Benchmark tested · 49/49 · Benchmark reportEN UA DE NL FR ES PL
  • Duct Network SolverDraw arbitrary duct networks with circular or rectangular ducts, junction and tee-loss arms, grilles, dampers and fans.Benchmark tested · 41/41 · Benchmark reportEN UA DE NL FR ES PL
  • Hydraulic Circuit SolutionsTwenty-two standard hydraulic circuits for heating and cooling in four categories — consumer control, generator connection, hydraulic decoupling and pump control…Benchmark tested · 203/203 · Benchmark reportEN UA DE NL FR ES PL
  • Control Loop LaboratoryAssemble a single control loop — setpoint, controller, actuator, plant, sensor, feedback and a disturbance injection — and watch the linear prediction and the non-linear simulation at the same time.Benchmark tested · 55/55 · Benchmark reportEN UA DE NL FR ES PL
  • PLC & DDC Control LabBuild PLC or DDC logic from IEC 61131-3 style blocks, connect it to a virtual tank, zone, valve and pump, inject faults and read the response.Benchmark tested · 114/114 · Benchmark reportEN UA DE NL FR ES PL
  • Functional Description BuilderControl narrative of one system: operating modes, GRAFCET/SFC sequences, control loops, interlocks and alarms, checked for unreachable steps, dead ends, non-deterministic transitions, unknown tags and setpoints outside the instrument range.Benchmark tested · 106/106 · Benchmark reportEN UA DE NL FR ES PL
  • Cause & Effect MatrixBuilds a cause and effect matrix — causes with voting, delay and bypass, effects with safe state, latch and reset — evaluates any cause scenario and reviews every combination for conflicts, coverage, reset and convention gaps.Benchmark tested · 100/100 · Benchmark reportEN UA DE NL FR ES PL
  • I/O ListBuilds a control system's I/O list: tag, signal and electrical type, range, fail state and SIL per signal, then allocates channels to cards and reports counts, spare and findings.Benchmark tested · 159/159 · Benchmark reportEN UA DE NL FR ES PL
  • Functional TestsGenerates one functional test per cause-and-effect cell, voting combination, sequence transition, mode edge and IO loop, records execution with evidence, and measures coverage of the control model.Benchmark tested · 128/128 · Benchmark reportEN UA DE NL FR ES PL

Occupational Safety 18

Project & Delivery 14

Tendering & Contracts 6

  • Award Criteria & Price Scoring DesignerWhich criteria, weights and price formula pick the best bid without rank reversal? Compares eight price-scoring methods on the same bids, shows live when adding or removing a bidder flips the ranking, prices one quality point in euro, maps the winner against the price weight and recommends a formula with its reasons.Benchmark tested · 243/243 · Benchmark reportEN UA DE NL FR ES PL
  • Commercial Bid NormalisationWhat does each bid really cost, apples to apples? Arithmetic check of the price schedule (KB 18.04.2017 art. 34), missing prices filled by the art. 86 formula, options per art. 87, rebates, currency, delivery-term (Incoterms 2020) gaps and payment terms as present value, with a ranked table for the award.Benchmark tested · 350/350 · Benchmark reportEN UA DE NL FR ES PL
  • Abnormally Low Tender CheckWhich bids must be asked to justify their price, and is the justification credible? Belgian art. 36 §4 check (15 % below the trimmed mean) with its conditions and exemptions, statistical screens, unit-price check per line against the median, and the justification checklist with the outcome and notifications.Benchmark tested · 415/415 · Benchmark reportEN UA DE NL FR ES PL
  • Bid / No-Bid DecisionIs this tender worth the bid cost? Rolls back the decision tree of one or two gates (qualification, then tender) to the expected value of bidding, gives the breakeven probability of award against the base rate 1/N and your hit rate, counts margin erosion, the opportunity cost of a fully booked team and a stated strategic value, scores the fit, checks knock-outs and shows what moves the answer.Benchmark tested · 241/241 · Benchmark reportEN UA DE NL FR ES PL
  • Subcontractor & Supplier Quote LevellingWhich quote is really cheapest? Fills every quote's scope gaps with plugs (own estimate, or the highest or mean price the other bidders gave), adds priced options, lands each quote on site in euro by its Incoterms 2020 rule with duty on the customs value, prices advances and stated commercial differences, ranks on paper and levelled, and shows how far your plugs may be wrong before the winner changes.Benchmark tested · 203/203 · Benchmark reportEN UA DE NL FR ES PL
  • Cost & Schedule Risk (Monte Carlo)How much contingency for P50 / P80, and which risks drive it? Simulates three-point cost ranges, risk events and a schedule of parallel paths together, with rank correlation, time-dependent cost and capped delay damages; gives the confidence of the base estimate, the contingency at any P, the S-curves, the joint cost-schedule confidence and a tornado of the drivers.Benchmark tested · 57/57 · Benchmark reportEN UA DE NL FR ES PL

Engineering Change & Plant Life 14

MEP Maintenance & Operations 6

  • MEP Asset CriticalityRanks building services assets A/B/C from safety, environment, service and cost consequence, verified redundancy, recovery against tolerable downtime and condition evidence.Benchmark tested · 91/91 · Benchmark reportEN UA DE NL FR ES PL
  • MEP Maintenance Strategy (RCM)Reliability-centred maintenance for building services: per failure mode the RCM decision diagram picks condition monitoring, scheduled replacement, a failure-finding test, run-to-failure or redesign, with the interval and the reason.Benchmark tested · 150/150 · Benchmark reportEN UA DE NL FR ES PL
  • Condition Monitoring AdvisorWhat to measure, how often, and does it pay? Usable P–F interval per technique, inspection interval, probability of catching the failure and cost-benefit ranges with the break-even downtime cost.Benchmark tested · 65/65 · Benchmark reportEN UA DE NL FR ES PL
  • MEP Maintenance PlannerTurns maintenance tasks into a 52/53-week calendar: hours per trade and week, season and shutdown windows, visit grouping, levelling within each task's tolerance, conflicts, budget and a CMMS work-order CSV.Benchmark tested · 25/25 · Benchmark reportEN UA DE NL FR ES PL
  • Critical Spares & RecoveryWhich spares to hold, share, contract or rent? Expected annual cost of no stock, k spares on site (Poisson demand over the lead time, service level), a pool shared between sites, a supplier agreement and temporary plant, with the recovery time of each option.Benchmark tested · 74/74 · Benchmark reportEN UA DE NL FR ES PL
  • MEP Renewal PlannerWhen to renew each building services asset: renewal year from condition (not age), criticality, refrigerant rules and support end; 25-year capex profile under a budget cap with the risk added by deferral.Benchmark tested · 77/77 · Benchmark reportEN UA DE NL FR ES PL

Plumbing & Sanitary 11

  • Sanitary Fixture CountMinimum WCs, urinals, washbasins, washing taps and showers per zone for the people working in a building — Belgian Codex, German ASR A4.1 or UK HSE L24 — and the fixture inventory for the whole plumbing package.Benchmark tested · 90/90 · Benchmark reportEN UA DE NL FR ES PL
  • Drinking Water Pipe SizingPeak flow from the fixtures (DIN 1988-300 per building type, or EN 806-3 loading units), pipe sizes of the service pipe, main, riser and floor branches by velocity and available pressure, residual pressure at the worst fixture and whether a booster is needed.Benchmark tested · 37/37 · Benchmark reportEN UA DE NL FR ES PL
  • Hot Water Storage & Heater SizingStorage volume against heater power for a design-day draw profile: the trade-off curve, reheat time, losses, instantaneous power, heat pump with booster and the 60 °C check.Benchmark tested · 82/82 · Benchmark reportEN UA DE NL FR ES PL
  • DHW Circulation & BalancingHeat losses of a hot-water circulation loop, circulation flow (DVGW W 553 split, thermostatic valves or no valves), exact temperatures in every riser, pump flow and head, balancing valve kv, annual loss in kWh and EUR, and the sections that fall below 55 °C.Benchmark tested · 47/47 · Benchmark reportEN UA DE NL FR ES PL
  • Legionella Risk & Dead LegsWhich obligations of the Flemish Legionellabesluit apply (high-risk, moderate-risk, the 40-person exemption), what laboratory results in KVE/l mean, dead-leg volumes against the 3-litre rule, an ordinal risk class with reasons and a control plan of periodic tasks for the maintenance planner.Benchmark tested · 53/53 · Benchmark reportEN UA DE NL FR ES PL
  • Backflow Protection Selector (EN 1717)Fluid category 1–5 at every connection point (library of 27 typical applications or a question chain), the EN 1717 protection units that are admissible there with the reason for every rejected one, the preferred unit, air-gap size, installation heights, drain and booster needs, and a maintenance list.Benchmark tested · 46/46 · Benchmark reportEN UA DE NL FR ES PL
  • Booster Set SizingIs a booster needed for this building and mains pressure? Floor-by-floor pressure balance (EN 806-2, DIN 1988-500), set pressure and pump head, DIN 1988-300 peak flow, duty and standby pumps, membrane vessel and starts per hour, break tank, 5 bar static limit with PRV floors or pressure zones, energy per year; hand-off to operatingpoint.Benchmark tested · 58/58 · Benchmark reportEN UA DE NL FR ES PL
  • Drainage & Venting (EN 12056-2)Discharge units per system I–IV, design flow Qww = K·√ΣDU, branch, stack and drain diameters from the EN 12056-2 tables, filling degree and velocity of drains by Prandtl–Colebrook, branch length limits, primary/secondary ventilation and air admittance valves.Benchmark tested · 75/75 · Benchmark reportEN UA DE NL FR ES PL
  • Wastewater Lifting Station (EN 12056-4)Fixtures below the backflow level: inflow from discharge units and rain, rising main kept between 0.7 and 2.3 m/s, pump duty point, sump useful volume from starts per hour and rising-main volume, single or duplex plant, backflow loop.Benchmark tested · 51/51 · Benchmark reportEN UA DE NL FR ES PL
  • Rainwater Reuse & InfiltrationRainwater tank for a roof and a demand (WC, laundry, garden) by a daily balance on 30 synthetic years of Uccle rain: coverage, rainwater used, overflow days, savings in EUR, yield-versus-volume curve, the DIN 1989-1 simplified size — and the minimum tank, infiltration and buffer volumes of the Flemish GSV Hemelwater 2023.Benchmark tested · 64/64 · Benchmark reportEN UA DE NL FR ES PL
  • Water Saving & Fixture EfficiencyBuilding water use by fixture class before and after efficient products (dual-flush WCs, urinal controls or waterless urinals, aerators, low-flow showers, push-button and sensor taps, greywater for flushing): m³ and litres per person and day, hot-water energy, CO₂, EUR per year, investment and simple payback, measures ranked.Benchmark tested · 38/38 · Benchmark reportEN UA DE NL FR ES PL

Buildings / Vertical Transport 3

  • Lift Waiting Time SimulatorAnimated, deterministic simulation of a lift group: how long people really wait (mean, 95th percentile, share over 60 s) and what changes it — call buttons vs destination keypads, dispatch rules, zoning, parking, habits, one more car or faster doors — with an A/B comparison on the same passengers.Benchmark tested · 30/30 · Benchmark reportEN UA DE NL FR ES PL
  • Lift Traffic Design (round-trip time)Classical up-peak lift design: round-trip time, interval, 5-minute handling capacity, %POP and an average waiting time estimate against criteria for the building use; sizing grid of cars × load × speed, zoning of tall buildings with express runs, and why one-floor trips never reach rated speed.Benchmark tested · 245/245 · Benchmark reportEN UA DE NL FR ES PL
  • Lift Energy & Efficiency ClassDaily and annual energy of one lift by the ISO 25745-2:2015 method — running plus idle and standby — with VDI 4707 classes, cost, CO₂ and a waterfall of what helps: regenerative drive, deep standby, LED car light.Benchmark tested · 45/45 · Benchmark reportEN UA DE NL FR ES PL

CCUS — CO₂ Capture, Transport & Storage 7

Oil, Gas & Hydrogen 24

  • Separator sizingVertical or horizontal gas-liquid separator sizing by the Souders-Brown method (GPSA Section 7, API Spec 12J): allowable gas velocity, vessel diameter, shell height or length, liquid volume and a to-scale sketch.Benchmark tested · 14/14 · Benchmark reportEN UA DE NL FR ES PL
  • Hydrate inhibitionMethanol or glycol injection rate for a required hydrate temperature depression by Hammerschmidt or Nielsen-Bucklin (GPSA Section 20): rich-phase inhibitor fraction, lean solution and pure inhibitor rates, and a rich-phase mass split diagram.Benchmark tested · 14/14 · Benchmark reportEN UA DE NL FR ES PL
  • Erosional velocityErosional velocity of gas, liquid and two-phase production lines by the API RP 14E C-factor equation (5th ed., 1991, reaffirmed 2013): no-slip mixture velocity against Ve = C/√ρm, velocity ratio, minimum inner diameter and a to-scale pipe cross-section.Benchmark tested · 14/14 · Benchmark reportEN UA DE NL FR ES PL
  • Flare radiationThermal radiation from an elevated flare by the API Std 521 Annex C point-source method: flame length, wind tilt, radiation at a receptor, minimum safe distance and stack height, with a grade-level radiation profile.Benchmark tested · 15/15 · Benchmark reportEN UA DE NL FR ES PL
  • Pipeline Corrosion Defect AssessmentWeb calculator that determines failure pressure, safe pressure, estimated repair factor (ERF) and maximum allowable length of single longitudinal corrosion metal-loss defects in oil, gas and hydrogen pipelines using ASME B31G original, modified B31G (0.85dL) and DNV-RP-F101 Part A/B.Benchmark tested · 29/29 · Benchmark reportEN UA DE NL FR ES PL
  • Pipeline Dent Strain CalculatorEstimates dent strain in oil, gas and hydrogen pipelines from measured dent geometry per ASME B31.8-2022 Nonmandatory Appendix R and checks it against acceptance limits.Benchmark tested · 21/21 · Benchmark reportEN UA DE NL FR ES PL
  • Pipeline Cathodic ProtectionSizes galvanic bracelet anodes for coated offshore or buried pipelines per DNV-RP-F103, DNV-RP-B401 and ISO 15589-2, from current demand to anode count.Benchmark tested · 23/23 · Benchmark reportEN UA DE NL FR ES PL
  • CO2 Corrosion Rate CalculatorEstimates CO2 corrosion rates of carbon steel in water-wet oil, gas, hydrogen-blend and CCUS pipelines using de Waard-Milliams 1991 and 1995 models.Benchmark tested · 20/20 · Benchmark reportEN UA DE NL FR ES PL
  • Gas dispersionDownwind distance and width of a continuous gas release to the LFL or a toxic level, using a Gaussian plume (Pasquill-Gifford) or Britter-McQuaid dense gas model.Benchmark tested · 8/8 · Benchmark reportEN UA DE NL FR ES PL
  • Hydrogen jet fireRelease rate, flame length and radiant heat flux of an ignited hydrogen leak, with distances to NFPA 2 and API 521 heat-flux criteria.Benchmark tested · 7/7 · Benchmark reportEN UA DE NL FR ES PL
  • Vapour cloud explosion overpressureSide-on overpressure, duration and impulse of a vapour cloud explosion at a receptor and distances to damage thresholds, by the TNO Multi-Energy and Baker-Strehlow-Tang methods.Benchmark tested · 15/15 · Benchmark reportEN UA DE NL FR ES PL
  • LOPA and SIL targetLayer of protection analysis for one scenario: mitigated frequency, required risk reduction and SIL per IEC 61511-1, and a PFDavg check of a proposed SIF.Benchmark tested · 8/8 · Benchmark reportEN UA DE NL FR ES PL
  • Methane emissions (OGMP 2.0)Annual CH4 inventory of an oil and gas facility from equipment counts, tanks, blowdowns and flaring, with CO2e, methane intensity and OGMP 2.0 level.Benchmark tested · 7/7 · Benchmark reportEN UA DE NL FR ES PL
  • Electrolyser SizingSizes a PEM, alkaline or SOEC electrolysis plant from rated power: polarisation curve, hydrogen output, system kWh/kg and efficiency on LHV and HHV basis, stacks, heat, water and voltage degradation over stack life.Benchmark tested · 16/16 · Benchmark reportEN UA DE NL FR ES PL
  • Blue Hydrogen SMR/ATRMass and energy balance of steam methane reforming or autothermal reforming with CO₂ capture: reformer equilibrium, shift, PSA, natural gas use (LHV), captured and emitted CO₂ and carbon intensity against the 3.38 kg CO₂e/kg low-carbon threshold.Benchmark tested · 16/16 · Benchmark reportEN UA DE NL FR ES PL
  • Hydrogen CompressorSizes a multi-stage intercooled hydrogen compressor with real-gas properties from GERG-2008 (ISO 20765-2:2015) and Leachman (2009): stage ratio, discharge temperatures, intercooler duty, shaft power and kWh per kg.Benchmark tested · 16/16 · Benchmark reportEN UA DE NL FR ES PL
  • Hydrogen Storage VesselSizes a bank of compressed-hydrogen vessels (Types I-IV, EN 17533:2020) with real-gas density from Leachman (2009): usable mass per vessel, number of vessels, ideal-gas error, burst pressure and LHV energy.Benchmark tested · 16/16 · Benchmark reportEN UA DE NL FR ES PL
  • Hydrogen Underground StorageWorking gas, cushion gas, energy (LHV), withdrawal rate and annual throughput of a hydrogen salt cavern from its volume, depth and the lithostatic pressure window (Caglayan et al. 2020), with Leachman (2009) real-gas density.Benchmark tested · 19/19 · Benchmark reportEN UA DE NL FR ES PL
  • LH2 Boil-offBoil-off of a vented liquid hydrogen tank from heat leak and ortho-para conversion (Petitpas, LLNL 2018): initial rate in %/day, mass and LHV energy lost over the storage period, and the para fraction at the end.Benchmark tested · 16/16 · Benchmark reportEN UA DE NL FR ES PL
  • Hydrogen blending into natural gasWobbe index, calorific value and relative density of a natural gas–hydrogen blend by ISO 6976:2016, the EN 16726 H-gas check and the maximum admissible hydrogen fraction.Benchmark tested · 14/14 · Benchmark reportEN UA DE NL FR ES PL
  • Hydrogen carriers compared: LH₂, ammonia, LOHCDelivered cost and energy efficiency of shipping hydrogen as liquid hydrogen, ammonia or LOHC, from conversion to reconversion, versus distance.Benchmark tested · 14/14 · Benchmark reportEN UA DE NL FR ES PL
  • Hydrogen refuelling: vehicle fillMass dispensed, final gas temperature and pressure, fill time and precooling energy of an H70 or H35 vehicle fill, checked against the SAE J2601:2020 limits.Benchmark tested · 14/14 · Benchmark reportEN UA DE NL FR ES PL
  • Hydrogen quantity, energy and fuel qualityConverts hydrogen between kg, Nm³, Sm³ and MWh or GJ (LHV/HHV), gives diesel, petrol, LPG, methanol and natural-gas equivalents with CO₂, and checks ISO 14687:2019 Grade D purity.Benchmark tested · 13/13 · Benchmark reportEN UA DE NL FR ES PL
  • Levelised cost of hydrogen and RFNBO checkLevelised cost of electrolytic hydrogen with cost breakdown, and the RFNBO check under EU delegated regulations 2023/1184 and 2023/1185.Benchmark tested · 20/20 · Benchmark reportEN UA DE NL FR ES PL

Structures & Mechanics 4

  • Beam DiagramsShear-force and bending-moment diagrams for beams. Choose the supports, add point, distributed and triangular loads or applied moments, and read the reactions and internal-force diagrams.Benchmark tested · 22/22 · Benchmark reportEN UA DE NL FR ES PL
  • Stress Transformation & Mohr CircleTransform 2D and full 3D stress, engineering load cases or strain rosettes, and explore Mohr–Coulomb effective stress with pore-pressure translation.Benchmark tested · 136/136 · Benchmark reportEN UA DE NL FR ES PL
  • 2D Frame / FEM WorkbenchBuild planar beam-column frames and run linear static, initial-stress P–Δ second-order, undamped modal or eigenvalue-buckling FEM: supports, springs, loads and combinations, reactions, deflections, N/V/M diagrams, natural frequencies, mode shapes and critical load factors.Benchmark tested · 41/41 · Benchmark reportEN UA DE NL FR ES PL
  • Debris Runout StudioBuild terrain, shell/wall geometry and mitigation, release shaped debris, model fragmentation, and map 2.5D Monte Carlo transit, landing, energy and runout hazard.Prototype · Benchmark reportEN UA DE NL FR ES PL

Physics & Mathematics 2

Optics & Photonics 6

  • Optical Bench 3DAn optical table in the browser: place lasers, Thorlabs catalogue lenses, mirrors, splitters, prisms, gratings, polarisers, fibres and detectors and trace every ray in 3D with glass dispersion, Fresnel losses and polarisation; spot size, power budget, light paths, parts list.Benchmark tested · 53/53 · Benchmark reportEN UA DE NL FR ES PL
  • Gaussian Beam & Mode MatchingLaser beam radius, waist, Rayleigh range, wavefront and Gouy phase through lenses, mirrors and plates (with M² and x/y astigmatism); two-lens mode matching, fibre coupling efficiency, ISO 11146 fit and two-mirror cavity stability.Benchmark tested · 55/55 · Benchmark reportEN UA DE NL FR ES PL
  • Lens Design & Image QualityHow good is the image of this lens system: real ray tracing of a prescription with catalogue glasses, paraxial data and pupils, spot diagrams against the Airy disc, ray fans, wavefront error, Strehl ratio and MTF, Seidel aberrations by surface, field curvature, distortion and chromatic focal shift; optimiser, Monte Carlo tolerances and nearest Thorlabs stock lenses.Benchmark tested · 56/56 · Benchmark reportEN UA DE NL FR ES PL
  • Thin-Film CoatingsReflectance, transmittance and absorptance of optical coatings versus wavelength and angle, s and p, with measured data of real coating materials: AR coatings, mirrors, edge and band-pass filters, metal mirrors, polarising cubes; colour, field inside the stack, thickness refinement and tolerances.Benchmark tested · 45/45 · Benchmark reportEN UA DE NL FR ES PL
  • Laser Safety (MPE, NOHD, Class, Eyewear)Is this laser dangerous, how far, which goggles? Eye and skin exposure limits (MPE) from Directive 2006/25/EC Annex II for CW, single and repetitive pulses, nominal ocular hazard distance with and without binoculars, required optical density and EN 207 scale number, and an indicative laser class.Benchmark tested · 561/561 · Benchmark reportEN UA DE NL FR ES PL
  • Machine-Vision Lens SelectorWhich lens and camera see my part sharp enough: focal length from sensor, field of view and working distance, pixels per feature, depth of field, diffraction and MTF at Nyquist, best f-number, motion blur and exposure, image circle and mount, telecentric check — with 75 Sony industrial sensors.Benchmark tested · 49/49 · Benchmark reportEN UA DE NL FR ES PL

Materials & Chemistry 3

Validation register · Disclaimer · Sitemap